Please use this identifier to cite or link to this item: http://localhost:80/xmlui/handle/123456789/14100
Full metadata record
DC FieldValueLanguage
dc.contributor.authorShehzadi, Naureen-
dc.contributor.authorHussain, Khalid-
dc.contributor.authorTanveer Khan, Muhammad-
dc.contributor.authorSalman, Muhammad-
dc.contributor.authorIslam, Muhammad-
dc.date.accessioned2022-11-28T04:39:00Z-
dc.date.available2022-11-28T04:39:00Z-
dc.date.issued2017-10-03-
dc.identifier.citationShehzadi, N., Hussain, K., Khan, M. T., Salman, M., & Islam, M. (2017). Evaluation of dynamics of derivatization and development of RP-HPLC method for the determination of amikacin sulphate. Pakistan journal of pharmaceutical sciences, 30(5).en_US
dc.identifier.issn1011-601X-
dc.identifier.urihttp://142.54.178.187:9060/xmlui/handle/123456789/14100-
dc.description.abstractThe absence of chromophore and/or conjugated system, prerequisite for UV and florescent light detection, or absorbance at very low wavelength necessitates the development of simple and reliable methods for the determination of amikacin sulphate. Therefore, the present study describes for the first time dynamics of the drug derivatization using ninhydrin reagent and development and validation of a simple RP-HPLC method, using diode array detector (DAD). The variables such as heating time, heating type, drug-reagent ratio, reagent composition and storage temperature of the derivative were optimized. The analyte and aqueous ninhydrin solution upon heating for 2.00-5.00 min produced the colored drug-derivative which was stable for one month at refrigeration. The derivatized drug (20.00µL) was eluted through a column – Eclipse DB-C18 (5.00 µm, 4.60×150.00 mm), maintained at 25°C- using isocratic mobile phase comprising water and acetonitrile (70:30, v/v) at a flow rate of 1.00 mL/min, and detected at 400 nm. The method was found to be reliable (98.08–100.72% recovery), repeatable (98.02–100.72% intraday accuracy) and reproducible (98.47– 101.27% inter day accuracy) with relative standard deviation less than 5%. The results of the present study indicate that the method is easy to perform, specific and sensitive, and suitable to be used for the determination of amikacin sulphate in bulk and pharmaceutical preparations using less expensive/laborious derivatization.en_US
dc.language.isoenen_US
dc.publisherKarachi: Faculty of Pharmacy & Pharmaceutical Sciences, Karachien_US
dc.subjectAmikacin sulphateen_US
dc.subjectDAD-Detectionen_US
dc.subjectDerivatizationen_US
dc.subjectNinhydrinen_US
dc.subjectRP-HPLCen_US
dc.titleEvaluation of dynamics of derivatization and development of RPHPLC method for the determination of amikacin sulphateen_US
dc.typeArticleen_US
Appears in Collections:No.5 September, 2017

Files in This Item:
File Description SizeFormat 
Paper-33.htm132 BHTMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.