Please use this identifier to cite or link to this item:
http://localhost:80/xmlui/handle/123456789/14753
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zhang, E | - |
dc.contributor.author | Chu, Fulong | - |
dc.contributor.author | Zhao, Tongde | - |
dc.contributor.author | Chai, Yuchao | - |
dc.contributor.author | Liang, Hao | - |
dc.contributor.author | Song, Shuliang | - |
dc.contributor.author | Ji, Aiguo | - |
dc.date.accessioned | 2022-12-06T07:05:54Z | - |
dc.date.available | 2022-12-06T07:05:54Z | - |
dc.date.issued | 2020-01-01 | - |
dc.identifier.citation | Zhang, E., Chu, F., Zhao, T., Chai, Y., Liang, H., Song, S., & Ji, A. (2020). Determination of fucoidan in rat plasma by HPLC and its application in pharmacokinetics. Pakistan Journal of Pharmaceutical Sciences, 33(1). | en_US |
dc.identifier.issn | 1011-601X | - |
dc.identifier.uri | http://142.54.178.187:9060/xmlui/handle/123456789/14753 | - |
dc.description.abstract | This is a new expanded method of determining the characterisation of fucoidan from Laminaria japonica (kelp) in rat plasma by high-performance liquid chromatography (HPLC) with fluorescence detection. We tagged fucoidan by fluoresce in isothiocyanate(FITC)for tracking and treated the plasma samples via protein precipitation with 10% trichloroacetic acid and methanol. Column chromatography separation was on a TSK-G4000sw column (7.8 mm × 300 mm, 5 m) by elution with 0.15 M NaCl. The quantification of fucoidan was performed by HPLC with fluorescence detection. The results suggested that the calibration curve for fucoidan concentration was linear dependent in the limits of 0.5–100μg/mL. The lower limit of quantitation (LLOQ) was 0.5μg/mL and the lower limit of detection (LLOD) was 0.15μg/mL.The intra-day and inter-day precision values were less than 13%and the accuracy ranged from96.83 to 100.03% at 3 different concentrations. The fucoidan stability of rat plasma at different temperatures and time-points was estimated. The extraction efficiencies ranged from 93.33 to 96.53%and the matrix effect ranged from 92.67 to 95.83%. Method selectivity was evaluated as well. We successfully studied the pharmacokinetic of fucoidan in rat plasma after oral by the validated method. Fucoidan was administered to rats intravenously at a dose of 6 mg/kg and orally at a dose of 20 mg/kg. The Cmax was 7.33μg/mL within 2 h by oral administration. The initial Cmax was 75.59μg/mL. The bioavailability of fucoidan after oral administration to rats was 8.91%. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Karachi: Faculty of Pharmacy & Pharmaceutical Sciences, Karachi | en_US |
dc.subject | Fucoidan, FITC labelling | en_US |
dc.subject | Laminaria japonica | en_US |
dc.subject | HPLC with fluorescence detection | en_US |
dc.subject | validation | en_US |
dc.title | Determination of fucoidan in rat plasma by HPLC and its application in pharmacokinetics | en_US |
dc.type | Article | en_US |
Appears in Collections: | Issue 1 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Paper-1.htm | 130 B | HTML | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.