DSpace logo

Please use this identifier to cite or link to this item: http://142.54.178.187:9060/xmlui/handle/123456789/1603
Title: Etch Induction Time in CR-39 Detectors Etched in Na2CO3 Mixed NaOH Solution
Authors: Ali, N.
Khan, E. U.
Khan, K.
Keywords: Natural Science
Chinese Physics Letters Etch Induction
CR-39 Detectors
Na2CO3
NaOH Solution
Issue Date: 1-Jan-2009
Publisher: Chinese Physical Society and IOP Publishing Ltd
Abstract: Six different solutions of 6M NaOH, containing different amounts of Na2CO3 at 70°C were used for the revelation of latent damage trails in CR-39 plastic track detectors. These detectors were earlier exposed to fission fragments from 252Cf source for 30 min in vacuum and were then etched in the respective solutions for different etching time intervals of 5–20 min starting from 5min up to 160min. The etch induction time in each detector was obtained by extrapolating the intersection of resulting curves of track lengths and track diameters with the time axis.
URI: http://142.54.178.187:9060/xmlui/handle/123456789/1603
ISSN: 26092901
Appears in Collections:Journals

Files in This Item:
File Description SizeFormat 
pdf.htm139 BHTMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.