Please use this identifier to cite or link to this item:
http://localhost:80/xmlui/handle/123456789/16063
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zeb-un-nisa | - |
dc.contributor.author | Muhammad Harris Shoaib | - |
dc.contributor.author | Syed Imran Ali | - |
dc.contributor.author | Mehwish Rizvi | - |
dc.contributor.author | Huma Ali | - |
dc.contributor.author | Rasheeda Fatima | - |
dc.contributor.author | Khan, Maqsood Ahmed | - |
dc.contributor.author | Sadia Suri Kashif | - |
dc.date.accessioned | 2023-01-19T04:07:45Z | - |
dc.date.available | 2023-01-19T04:07:45Z | - |
dc.date.issued | 2018-05-02 | - |
dc.identifier.citation | Shoaib, M. H., Ali, S. I., Rizvi, M., Ali, H., Fatima, R., Khan, M. A., & Kashif, S. S. (2018). Development and validation of RP-HPLC method with UV detection to determine and quantify dimenhydrinate in human plasma. Pakistan Journal of Pharmaceutical Sciences, 31. | en_US |
dc.identifier.issn | 1011-601X | - |
dc.identifier.uri | http://142.54.178.187:9060/xmlui/handle/123456789/16063 | - |
dc.description.abstract | A simple, sensitive and rigorous method for estimation of dimenhydrinate in human plasma was searched and its validation was carried out. LLE (Liquid-Liquid extraction) of analyte with mixture of Hexane and ethyl acetate (1:1 v/v) was carried out for the preparation of Plasma Samples, Chromatographic elution of dimenhydrinate was conducted in human plasma and mobile phase with C-18 bonda Pack column (10µm; 250 × 4.6), using a mobile phase consisting a solution of ammonium bicarbonate in water and methanol at a flow rate of 0.5ml/minute with UV detection at 229 nm. The resolution of dimenhydrinate was well performed from plasma components. This method was validated and exhibited linearity with concentration range of 6 to 380ng/ml of dimenhydrinate in plasma. The Intra day precision was 89.2 to 96.89% and Inter day precision was 88.6% to 93.26%, the average recovery of dimenhydrinate was 97.02%. The efficacy of extraction was proved by above mentioned results. 2ng/ml and 6ng/ml, were appraised as the LOD and LOQ of dimenhydrinate, stability studies disclosed that dimenhydrinate exhibited stability in Plasma after Freeze & thaw cycles and upon -20o C storage, the method was developed well. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Karachi: Faculty of Pharmacy & Pharmaceutical Sciences University of Karachi | en_US |
dc.subject | Dimenhydrinate | en_US |
dc.subject | human plasma | en_US |
dc.subject | HPLC | en_US |
dc.subject | limit of detection | en_US |
dc.subject | analyte | en_US |
dc.title | Development and validation of RP- HPLC method with UV detection to determine and quantify dimenhydrinate in human plasma | en_US |
dc.type | Article | en_US |
Appears in Collections: | Issue No.3 (Supplementary) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2-SUP-841.htm | 146 B | HTML | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.