dc.contributor.authorZeb-un-nisa-
dc.contributor.authorMuhammad Harris Shoaib-
dc.contributor.authorSyed Imran Ali-
dc.contributor.authorMehwish Rizvi-
dc.contributor.authorHuma Ali-
dc.contributor.authorRasheeda Fatima-
dc.contributor.authorKhan, Maqsood Ahmed-
dc.contributor.authorSadia Suri Kashif-
dc.date.accessioned2023-01-19T04:07:45Z-
dc.date.available2023-01-19T04:07:45Z-
dc.date.issued2018-05-02-
dc.identifier.citationShoaib, M. H., Ali, S. I., Rizvi, M., Ali, H., Fatima, R., Khan, M. A., & Kashif, S. S. (2018). Development and validation of RP-HPLC method with UV detection to determine and quantify dimenhydrinate in human plasma. Pakistan Journal of Pharmaceutical Sciences, 31.en_US
dc.identifier.issn1011-601X-
dc.identifier.urihttp://142.54.178.187:9060/xmlui/handle/123456789/16063-
dc.description.abstractA simple, sensitive and rigorous method for estimation of dimenhydrinate in human plasma was searched and its validation was carried out. LLE (Liquid-Liquid extraction) of analyte with mixture of Hexane and ethyl acetate (1:1 v/v) was carried out for the preparation of Plasma Samples, Chromatographic elution of dimenhydrinate was conducted in human plasma and mobile phase with C-18 bonda Pack column (10µm; 250 × 4.6), using a mobile phase consisting a solution of ammonium bicarbonate in water and methanol at a flow rate of 0.5ml/minute with UV detection at 229 nm. The resolution of dimenhydrinate was well performed from plasma components. This method was validated and exhibited linearity with concentration range of 6 to 380ng/ml of dimenhydrinate in plasma. The Intra day precision was 89.2 to 96.89% and Inter day precision was 88.6% to 93.26%, the average recovery of dimenhydrinate was 97.02%. The efficacy of extraction was proved by above mentioned results. 2ng/ml and 6ng/ml, were appraised as the LOD and LOQ of dimenhydrinate, stability studies disclosed that dimenhydrinate exhibited stability in Plasma after Freeze & thaw cycles and upon -20o C storage, the method was developed well.en_US
dc.language.isoenen_US
dc.publisherKarachi: Faculty of Pharmacy & Pharmaceutical Sciences University of Karachien_US
dc.subjectDimenhydrinateen_US
dc.subjecthuman plasmaen_US
dc.subjectHPLCen_US
dc.subjectlimit of detectionen_US
dc.subjectanalyteen_US
dc.titleDevelopment and validation of RP- HPLC method with UV detection to determine and quantify dimenhydrinate in human plasmaen_US
dc.typeArticleen_US