Please use this identifier to cite or link to this item: http://localhost:80/xmlui/handle/123456789/1610
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSattar, Amjad-
dc.contributor.authorKhan, Sohail Ahmed-
dc.contributor.authorQamari, Nauman Al--
dc.contributor.authorAdel, Hatem-
dc.contributor.authorAdil, Syed Omair-
dc.date.accessioned2019-11-20T11:10:39Z-
dc.date.available2019-11-20T11:10:39Z-
dc.date.issued2019-11-01-
dc.identifier.urihttp://142.54.178.187:9060/xmlui/handle/123456789/1610-
dc.description.abstractThis study was conducted to determine the diagnostic accuracy of CT-guided core needle biopsy (CNB) using coaxial technique of pulmonary lesions, its complications and factors affecting them. A total of 122 patients with suspected lung malignancy underwent CT-guided CNB. Final diagnosis was confirmed by histopathology. There were 84 (89.4%) true positive while 26 (92.9%) true negative cases. Diagnostic accuracy, sensitivity, specificity, PPV, NPV, and overall diagnostic accuracy were 97.67%, 72.22%, 89.36%, 92.86% and 90.16% respectively. Pneumothorax was the only complication observed in 10 (8.2%) patients. The odds of pneumothorax was found to be 10.72 times higher among patients with 2.5cm of size of lesions (AOR 10.72, 95% CI 1.49-76.77) while 86% lower among patients having prone position (AOR 0.14, 95% CI 0.021-0.96). Results indicate that percutaneous CT guided biopsy of pulmonary lesions using coaxial technique is a safe procedure with a high diagnostic accuracy and lesser risk of major complications.en_US
dc.language.isoen_USen_US
dc.publisherJ Pak Med Assocen_US
dc.subjectMedical and Health Sciencesen_US
dc.subjectSpiral Computed Tomographyen_US
dc.subjectCore Needle Biopsyen_US
dc.subjectLungen_US
dc.subjectMetastasisen_US
dc.titleDiagnostic accuracy and associated complications of percutaneous computed tomography guided core needle biopsy of pulmonary lesions using coaxial techniqueen_US
dc.typeArticleen_US
Appears in Collections:Journals

Files in This Item:
File Description SizeFormat 
9387.htm107 BHTMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.