DSpace logo

Please use this identifier to cite or link to this item: http://142.54.178.187:9060/xmlui/handle/123456789/16346
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYan, Huiyu-
dc.contributor.authorTao, Lina-
dc.contributor.authorQu, Xiaoyu-
dc.contributor.authorZhou, Liting-
dc.contributor.authorZhang, Sixi-
dc.date.accessioned2023-01-20T07:09:01Z-
dc.date.available2023-01-20T07:09:01Z-
dc.date.issued2018-05-19-
dc.identifier.citationYan, H., Tao, L., Qu, X., Zhou, L., & Zhang, S. (2018). Quantitative determination of mogroside V in rat plasma by LC-MS/MS and its application to a pharmacokinetic study. Pakistan Journal of Pharmaceutical Sciences, 31(3).en_US
dc.identifier.issn1011-601X-
dc.identifier.urihttp://142.54.178.187:9060/xmlui/handle/123456789/16346-
dc.description.abstractMogroside V is the most abundant (approximately 0.50%) cucurbitane-type triterpene glycoside in Siraitia grosvenorii and exhibits significant antitussive, expectorant, anti-carcinogenic, and anti-inflammatory effects. A sensitive, robust and selective liquid chromatography tandem with mass spectrometry (LC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of mogroside V in rat plasma. Samples were prepared through an one-step deproteinization procedure with 250 µL of methanol to a 75-µL plasma sample. Plasma samples were effectively separated on a Shiseido Capcell Pak UG120 C18 column (2.0 × 50mm, 3.0µm) using a mobile phase consisting of methanol: water (60:40, v/v) with an isocratic elution program. The running time for each sample was 7.0 min and the elution times of mogroside V and IS were 2.0 and 4.8 min, respectively. The detection relied on a triplequadrupole tandem with mass spectrometer equipped with negative-ion electrospray ionization interface by selectedreaction monitoring (SRM) of the transitions at m/z 1285.6 → 1123.7 for mogroside V and m/z 1089.6 → 649.6 for IS. The calibration curve was linear over the range of 96.0–96000ng/mL with a limit of quantitation (LOQ) of 96.0ng/mL. Intra-day and inter-day precisions were both <10.1%. Mean recovery and matrix effect of mogroside V in plasma were in the range of 91.3-95.7% and 98.2-105.0%, respectively. This method was successfully applied in the pharmacokinetic study of mogroside V after intravenous or intraperitoneal administration of 1.12mg/kg mogroside V in rats.en_US
dc.language.isoenen_US
dc.publisherKarachi: Faculty of Pharmacy & Pharmaceutical Sciences University of Karachien_US
dc.subjectMogroside Ven_US
dc.subjectLC-MS/MSen_US
dc.subjectPharmacokinetic studyen_US
dc.titleQuantitative determination of mogroside V in rat plasma by LCMS/MS and its application to a pharmacokinetic studyen_US
dc.typeArticleen_US
Appears in Collections:Issue 03