Please use this identifier to cite or link to this item: http://localhost:80/xmlui/handle/123456789/18487
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKHAN, SHAKEEL QUTUB-
dc.contributor.authorAMTUL HAI SOBIA-
dc.contributor.authorHASAN MEHDI-
dc.contributor.authorBABUR ASHRAF-
dc.date.accessioned2023-03-13T06:52:46Z-
dc.date.available2023-03-13T06:52:46Z-
dc.date.issued2017-06-17-
dc.identifier.citationKhan, S. Q., Sobia, A. H., Mehdi, H., & Ashraf, B. (2017). Quality assessment of lateral cephalometric radiographs. Pakistan Oral & Dental Journal, 37(2), 265-268.en_US
dc.identifier.issn1012-8700-
dc.identifier.urihttp://142.54.178.187:9060/xmlui/handle/123456789/18487-
dc.description.abstractLateral Cephalometric radiograph is a valuable diagnostic tool for the orthodontist. Quality assurance of radiographs is important as unsatisfactory radiograph can alter patient diagnosis and treatment plan. The main objectives of this study were to assess quality of lateral cephalometric radiographs using three point quality scale and compare the results achieved with minimum targets proposed by NRPB in “Guidance Notes For Dental Practitioners On The Safe Use Of X-Ray Equipment.” Radiographs were obtained from pretreatment records of patient undergoing orthodontic treatment. With exception to basic information section, each aspect of lateral cephalometric radiographic image summarized in “Standards by Faculty of Dental Surgery” was rated by using a three point quality scale proposed by National Radiological Protection Board. Minimum targets recommended in “Guidance Notes for Dental Practitioners on the Safe Use of X-ray Equipment” were used to compare results. Out of all the attributes assessed on 266 radiographs, point “B” was the most clearly identifiable attribute while contrast was least clear attribute. 185 (69.5%) radiographs assessed were classified as excellent, 44 (16.5%) radiographs were diagnostically acceptable, while only 37 (14%) radiograph were rated as diagnostically unacceptable which clearly did not meet the targets recommended by NRPB. Quality of Lateral Cephalometric radiograph must be assessed regularly in order to prevent repetition and excessive exposure of radiation to patientsen_US
dc.language.isoenen_US
dc.publisherIslamabad: Prof Ahmad Iqbal for Pakistan Society for Promotion of Oral & Dental Researchen_US
dc.subjectLateral Cephalometricen_US
dc.subjectRadiographen_US
dc.subjectQuality Assuranceen_US
dc.subjectRadiationen_US
dc.titleQUALITY ASSESSMENT OF LATERAL CEPHALOMETRICRADIOGRAPHSen_US
dc.typeArticleen_US
Appears in Collections:Issue 02

Files in This Item:
File Description SizeFormat 
83.htm128 BHTMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.