Please use this identifier to cite or link to this item: http://localhost:80/xmlui/handle/123456789/18668
Title: KINETIC INVESTIGATION OF CHROMIUM (III) REMOVAL BY STRONG ACID EXCHANGER AMBERLYST-15(H+ )
Authors: K. H. Shah
S. Mustafa
A. Naeem
M. Waseem
T. Ahmad
Keywords: : Chromium(III)
ion exchange
Amberlyst-15(H+ )
Film Diffusion; metal removal
Issue Date: 6-Dec-2010
Publisher: Peshawar: Materials Research Laboratory Department of Physics University of Peshawar, Pakistan
Citation: Mustafa, S., Shah, K. H., Naeem, A., Waseem, M., Ahmad, T., & Sarfraz, S. (2009). Kinetic Investigation of Chromium (III) Removal by Strong Acid Exchanger Amberlite IR-120 (H+). J. Pak. Mater. Soc, 3(1), 3-6.
Abstract: Cr(III) sorption on the strong acid exchanger Amberlyst-15(H+ ) is studied as a function of time and temperature using basic chromium sulphate [Cr4(SO4)5(OH)2] solution. Increase in temperature has a positive effect on Cr(III) sorption. The pH is observed to decrease during Cr(III) sorption with the passage of time. The film diffusion model is applied to explain the kinetic data and the exchange rate is found to be governed by the film diffusion process. From the rate constant values, the energies of activation are calculated using the Arrhenius equation. The low activation energy confirmed the diffusional nature of the sorption process.
URI: http://142.54.178.187:9060/xmlui/handle/123456789/18668
ISSN: 2070-772X
Appears in Collections:Issue 02

Files in This Item:
File Description SizeFormat 
115-120.htm122 BHTMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.