DSpace logo

Please use this identifier to cite or link to this item: http://142.54.178.187:9060/xmlui/handle/123456789/18808
Title: Casagrande Liquid Limit Testing Of Jamshoro Soil By One Point
Authors: Method M. Aslam
S. N. R. Shah
S. H. Otho
Keywords: Jamshoro
Liquid Limits
Casagrande
Clayey Soil
One Point Formula
Index Value
Issue Date: 11-May-2016
Publisher: Taxila: University of Engineering and Technology, Taxila
Citation: Aslam, M., Shah, S. N. R., & Otho, S. H. (2016). Casagrande liquid limit testing of Jamshoro soil by One Point method. University of Engineering and Technology Taxila. Technical Journal, 21(2), 85.
Abstract: The Liquid limit (LL) tests are considered essential to determine the index properties of soil. Casagrande liquid limit test is one of these tests and universally recognized for soil testing. The purpose of this research work is to introduce the constant values of index (e) and Number of Blows for A-7-6 (AASHTO Classification) clayey shale type soils using one point formula. 100 samples ofA-7-6 soil were collected from Jamshoro (Pakistan) zone and multi point Casagrande liquid limit laboratory tests were performed. After obtaining test results, samples were squeezed out with appropriate range of LL covering maximum number of samples. Suitable range of number of blows was chosen and the most appropriate index (e) value for selected soil samples was calculated. The experimental results were compared with one point formula results. The reliability of LL between experimental results and one point formula results exhibited excellent relationship.
URI: http://142.54.178.187:9060/xmlui/handle/123456789/18808
ISSN: 2313-7770
Appears in Collections:Issue 02



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.