Please use this identifier to cite or link to this item: http://localhost:80/xmlui/handle/123456789/19741
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYASMIN NERGIS-
dc.contributor.authorMUGHAL SHARIF-
dc.contributor.authorM. AFZAL FAROOQ-
dc.date.accessioned2023-10-02T05:33:32Z-
dc.date.available2023-10-02T05:33:32Z-
dc.date.issued2010-12-03-
dc.identifier.citationNergis, Y., Sharif, M., & Farooq, M. A. (2010). Chemical oxygen demand (COD) fractions characterization of Karachi metropolitan wastewater. Journal of the Chemical Society of Pakistan, 32(6), 711-716.en_US
dc.identifier.issn0253-5106-
dc.identifier.urihttp://142.54.178.187:9060/xmlui/handle/123456789/19741-
dc.description.abstractTo prove the hypothesis that the inert products are given to environment due to biological degradation of substrate in activated sludge operations. This study was design to investigate the inert fractions of chemical oxygen demand (COD) in metropolitan effluent. An aerobic batch reactor system was experimentally setup and maintained up to 480 hours. At the end of operations, COD compositions of metropolitan wastewater were found to be STO = 131 mg/L, XSO = 63 mg/L, CSO = 178 mg/L, SSO = 115 mg/L, SI = 16 mg/L, XI = 218 mg/L, respectively. At the end of operations, COD compositions of metropolitan wastewater were found to be STO = 131 mg/L, XSO = 63 mg/L, CSO = 178 mg/L, SSO = 115 mg/L, SI = 16 mg/L, XI = 218 mg/L respectively. This study is focused on inert COD fractions of metropolitan wastewater which consist of domestic as well as local industrial effluent. Soluble inert COD (SI) must be determined for discharge standards since it did not give any reaction in activated sludge system and was given with wastewater discharge. However particulate inert COD (XI) accumulated in system depending on sludge retention time due to it is only wasted from system by wasted sludge. Experimental techniques were used attained Zohu X. et al. [1, 2] in order to determine directly influent particulate and soluble inert fractions. The experimental study was carried out until COD profile reached to steady state or depletion of degradable substrate.The conventional parameters of municipal characterization were as follows: total COD (CTO) = 412 mg/L, total soluble COD (STO) = 131 mg/L, biochemical oxygen demand (BOD5) = 197 mg/L, total biochemical oxygen demand (BODt) = 351 mg/L, total suspended solids (TSS) = 264 mg/L, ammonia nitrogen (NH3-N) = 26.6 mg/L, grease & oil (G & O) = 17.5 mg/L and pH were 7.4 SU, respectively.en_US
dc.description.sponsorshipThe chemical society of Pakistan is an approved society from the PSF.en_US
dc.language.isoenen_US
dc.publisherKarachi: The Chemical Society of Pakistanen_US
dc.titleChemical Oxygen Demand (COD) Fractions Characterization of Karachi Metropolitan Wastewateren_US
dc.typeArticleen_US
Appears in Collections:Issue 06