DSpace logo

Please use this identifier to cite or link to this item: http://142.54.178.187:9060/xmlui/handle/123456789/19861
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNawal Ahmed Alarfaj-
dc.contributor.authorFatma Ahmed, Aly-
dc.contributor.authorSalma Ali, Al-Tamimi-
dc.contributor.authorMaha Farouk, El-Tohamy-
dc.date.accessioned2023-10-23T04:12:27Z-
dc.date.available2023-10-23T04:12:27Z-
dc.date.issued2013-10-20-
dc.identifier.citationAlarfaj, N. A., Aly, F. A., Al-Tamimi, S. A., & El-Tohamy, M. F. (2013). Enhanced silver nanoparticle chemiluminescence method for the determination of gemifloxacin mesylate using sequential injection analysis. J. Chem. Soc. Pak, 35(5), 13-19.en_US
dc.identifier.issn0253-5106-
dc.identifier.urihttp://142.54.178.187:9060/xmlui/handle/123456789/19861-
dc.description.abstractA sequential injection analysis (SIA) with chemiluminescence detection has been proposed for the determination of the antibiotic gemifloxacin mesylate (GFX). The developed method is based on the enhancement effect of silver nanoparticles (Ag NPs) on the chemiluminescence (CL) signal of luminol-potassium ferricyanide reaction in alkaline medium. The introduction of gemifloxacin in this system produced a significant decrease in the CL intensity in presence of (Ag NPs). The optimum conditions for CL emission were investigated. Linear relationship between the decrease in CL intensity and concentration was obtained in the range 0.01-1000 𝑛g mL⁻¹, (r = 0.9997) with detection limit of 2.0 pg mL⁻¹and quantification limit of 0.01 𝑛g mL⁻¹. The relative standard deviation was 1.3 %. The proposed method was employed for the determination of gemifloxacin in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated, and no interference was found from these excipients. The obtained SIA results were statistically compared with those obtained from a reported method and did not show any significant difference at confidence level 95%.en_US
dc.description.sponsorshipThe chemical society of Pakistan is an approved society from the PSF.en_US
dc.language.isoenen_US
dc.publisherHEJ Research Institute of Chemistry, University of Karachi, Karachi.en_US
dc.subjectSilver nanoparticleen_US
dc.subjectGemifloxacin mesylateen_US
dc.subjectLuminol- potassium ferricyanide systemen_US
dc.subjectSequential injection analysisen_US
dc.subjectChemiluminescenceen_US
dc.titleEnhanced Silver Nanoparticle Chemiluminescence Method for the Determination of Gemifloxacin Mesylate using Sequential Injection Analysisen_US
dc.typeArticleen_US
Appears in Collections:Issue 05

Files in This Item:
File Description SizeFormat 
ViewByVolume.aspx?v=194&i=VOLUME%2035,%20NO5,%20OCT-2013.htm147 BHTMLView/Open