DSpace logo

Please use this identifier to cite or link to this item: http://142.54.178.187:9060/xmlui/handle/123456789/19910
Title: New High Performance Liquid Chromatographic Method for Simultaneous Determination of Diclofenac and Meloxicam in Oral Formulation of Liposomes and Human Plasma
Authors: ASADULLAH MADNI
MAHMOOD AHMAD
MUHAMMAD USMAN
MALIK MUHAMMAD ZUBAIR
MUHAMMAD QAMAR-UZ-ZAMAN
HAJI MUHAMMAD SHOAIB
ABUBAKAR MUNIR
SHUJAT ALI KHAN
MUHAMMAD NAEEM AMIR
MUHAMMAD SALEEM QURESHI
Issue Date: 20-Oct-2010
Publisher: HEJ Research Institute of Chemistry, University of Karachi, Karachi.
Citation: Madni, A., Ahmad, M., Usman, M., Zubair, M. M., Shoiab, H. M., Khan, S. A., & Qureshi, M. S. (2010). New high performance liquid chromatographic method for simultaneous determination of diclofenac and meloxicam in oral formulation of liposomes and human plasma. Journal of the chemical society of Pakistan, 32(5), 654-661.
Abstract: A new, easy and consistent reversed-phase high-performance liquid chromatographic method with diode array detection has been developed and validated for the simultaneous determination of diclofenac potassium (DP) and meloxicam (MLX) in liposome, marketed brands and human plasma. Microextraction method based on liquid-liquid extraction principal was used to extract drug from plasma matrix. The optimized mobile phase was used in the molar ratio of 20:20:60 (v/v/v) mixture of acetonitrile, methanol and 20 x 10⁻³ M potassium dihydrogen phosphate buffer (pH 3.7), pumped at an optimized flow rate of 1.0 mL.min⁻¹. The linearity was performed in the concentration range of 15 ng.mL⁻¹ to 10µg.mL⁻¹ with r² of 0.9989 ± 0.13 and 0.9979 ± 0.11 (n = 6) for DP and MLX, respectively. The assay was repeatable at concentration levels of 10 ng.mL⁻¹, 1 µg.mL⁻¹ and 10 µg.mL⁻¹ with coefficient of variation of 0.168 - 0.603% for 10 ng.mL⁻¹ (DP), 15 ng.mL⁻¹ (MLX) and 1 µg.mL⁻¹ &10 µg.mL⁻¹ for DP and MLX. The LOD values were 3 and 5 ng.mL⁻¹, while values of LOQ were 10 and 15 ng.mL⁻¹, for DP and MLX. The present method is applicable in routine quality control operations, advanced drug delivery formulations (Liposomes) and in human Plasma samples for pharmacokinetics and bioequivalence studies.
URI: http://142.54.178.187:9060/xmlui/handle/123456789/19910
ISSN: 0253-5106
Appears in Collections:Issue 05

Files in This Item:
File Description SizeFormat 
ViewByVolume.aspx?v=9&i=VOLUME%2032,%20NO5,%20OCT%202010#google_vignette.htm163 BHTMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.